Modular Cold Room Tunelgroup Cooling Systems

Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.

  • Manufacturer of integrated container rack cold aisle immersion liquid cooling systems

    Manufacturer of integrated container rack cold aisle immersion liquid cooling systems

    High-density, liquid-cooled, rack-based servers for data centers, edge computing, and harsh environments. LiquidCool Solutions is the only company combining Total Liquid Immersion with Directed Flow (direct-to-chip) in a standard 19″ rack. It is installed outside the white space, engineered to serve entire data halls. With over a decade of experience cooling racks beyond 400 kW, we deliver end‑to‑end liquid cooling, with advanced technologies like Coolant Distribution Units. Ingrasys offers a complete line of rack-level liquid cooling solutions based on where the heat is exhausted in the data center. Refer to the chart below for valuable insights into elevating your data center's efficiency and fostering a more sustainable future.

    [PDF Version]
  • Energy-saving cold aisle computer room

    Energy-saving cold aisle computer room

    The hot and cold aisles in the data center are part of an energy-efficient layout for server racksand other computing equipment. The goal of a hot/cold aisle configuration is to manage airflow in a way that c.


  • Temperature in enclosed cold aisle server room

    Temperature in enclosed cold aisle server room

    ASHRAE recommends keeping server rooms between 64. Although ventilation and air-recycling systems offer many ways to achieve this temperature range, one of the most efficient and cost-effective methods is aisle containment. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. In this guide, we'll break down how hot aisle and cold aisle configurations. Containment refers to physical barriers used in a hot aisle/cold aisle layout that further eliminate the mixing of cold ("supply") air and hot exhaust air. Containment barriers include plastic curtains and Plexiglas sheets that prevent hot exhaust air from flowing over the tops of server racks. Cold Aisle Containment isolates the cooled supply air from the cooling units within direct proximity of the air intake of critical equipment. Servers pull in air at consistent, low.

    [PDF Version]
  • Single cold aisle in the computer room

    Single cold aisle in the computer room

    Cold aisle containment systems use doors at aisle ends, ceiling panels or lids above racks, and structural frames to create enclosed zones where cold supply air flows directly to IT equipment intakes. Without containment, cold supply and hot exhaust air mix throughout the data. Hot aisle and cold aisle containment are foundational concepts in data center design. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. In this guide, we'll break down how hot aisle and cold aisle configurations. Assuming a computer room is configured in such a way that either is an option, hot aisle containment may be seen as the better option because it has some thermal efficiency and ride-through advantages. However, because every computer room is unique, there is no one definitive solution. I break down ASHRAE's latest guidelines and settle the HAC vs.

    [PDF Version]
  • High-density cold aisle in wholesale computer room

    High-density cold aisle in wholesale computer room

    The hot and cold aisles in the data center are part of an energy-efficient layout for server racksand other computing equipment. The goal of a hot/cold aisle configuration is to manage airflow in a way that c.